Product ID:NEW TONER FOR ACTION LASER 1000/1500
MSDS Date:09/21/1992
FSC:6850
NIIN:00N055017
MSDS Number: CBVWL
Responsible Party
OSAKA 541, JAPAN
Emergency Phone: 06-271-2251
Info Phone: 06-271-2251
Cage: S4049
Contractor
Telephone: 05-271-2251
Cage: S4049
Ingredients
POLYESTER RESIN
Fraction By Weight: >85%
OSHA PEL N/K
ACGIH TLV: N/K
CARBON BLACK
CAS: 1333-86-4
RTECS: FF5800000
Fraction By Weight: 1-5%
OSHA PEL 3.5 MG/M3
ACGIH TLV: 3.5 MG/M3
ORGANIC PIGMENT
CAS: 32517-36-5
Fraction By Weight: 1-3%
OSHA PEL N/K
ACGIH TLV: N/K
PROPENE, POLYMERS; (POLYPROPYLENE)
CAS: 9003-07-4
RTECS: UD1842000
Fraction By Weight: 1-3%
OSHA PEL N/K
ACGIH TLV: N/K
SILICA GEL; (AMORPHOUS SILICA)
CAS: 112945-52-5
RTECS: VV7310000
Fraction By Weight: <1%
OSHA PEL 6 MG/M3
ACGIH TLV: 10 MG/M3
Hazards
LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MIN RESP TRACT IRRIT MAY OCCUR
AS W/EXPOS TO LG AMTS OF ANY NONTOXIC DUST. MAY CAUSE COUGH & RAISE
PHLEGM. TONER REPRESENTS LOW HAZ FOR USUAL OCCUP SETTINGS. BASED ON
AVAIL DATA, HUMAN EXPOS TO TONER HAS BEEN SHOWN TO CAUSE MIN RESP
TRACT IRRIT AS MAY OCCUR W/LG AMTS OF ANY NON-TOX DUSTS. THE (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:RSLTS OF ONE ANIMAL STUDY WHERE RATS
INHALED TONER THAT WAS 10 TIMES MORE RESPIRABLE THAN COMMERCIALLY
AVAIL TONER WERE OBSERVED TO HAVE NO LUNG CHANGES AT LOW EXPOS
(MOST RELEVANT LEVEL TO P OTNTL HUMAN EXPOS). AT HIGHER LEVELS A
SLIGHT DEGREE OF LUNG FIBROSIS WAS OBSERVED DUE TO EXCESSIVE AMTS
OF DUST(SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:WASH NOSTRILS, RINSE MOUTH. INGEST:DILUTE STOMACH
CONTENTS W/SEVERAL GLASSES OF WATER. EYES:FLUSH W/WATER FOR AT
LEAST 15 MINUTES. SKIN:WASH W/SOAP & WATER.
Fire Fighting
Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:IF DISPERSED IN AIR, TONER, LIKE MOST
FINELY DIVIDED ORGANIC POWDERS, MAY FORM AN EXPLOSIVE MIXTURE.
Accidental Release
Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE.
Other Precautions:TONER, AS A MIXTURE, IS CONSIDERED AS NUISANCE DUST.
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE REQUIRED WHEN USED AS INTENDED IN
MINOLTA EQUIPMENT.
Protective Gloves:NONE REQD WHEN USED AS INTENDED (SUPDAT)
Eye Protection:ANSI APPROVED SAFETY GLASSES .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE.
Supplemental Safety and Health
EFTS OF OVEREXP:RETAINED IN THE LUNGS FOR A PROLONGED INTERVAL. PROT
GLOVES:IN MINOLTA EQUIPMENT.
Chemical Properties
Spec Gravity:1.2 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK POWDER; FAINT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION ARE TOXIC.
AVOID BREATHING OF SMOKE.
Disposal
Waste Disposal Methods:WASTE MAY BE DISPOSED OR INCINERATED UNDER
CONDITIONS WHICH MEET ALL FEDERAL, STATE & LOCAL ENVIRONMENTAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.